Testing Condition
Unless otherwise specified in the testing project, all tests in this specification shall be conducted under the following conditions:
Environmental temperature: 25 ± 2 ℃;
Relative humidity: 65% ± 20%
Test Instrumentation & Device Characteristics
The accuracy of the voltage measuring instrument should not be lower than level 0.5, and the internal resistance should not be less than 10k Ω/V; The accuracy of the current measuring instrument should not be lower than level 0.5; The accuracy of the instrument used for measuring time shall not be less than ± 0.1%; The temperature measuring instrument should not be lower than ± 1 ℃; The voltage output and detection accuracy of the battery charge and discharge tester shall not be less than ± 0.5%; The current output and detection accuracy shall not be less than ± 0.1%;
Safety Performance Requirements
| Item | Test Method | Require |
|---|---|---|
| Short Circuit | After being fully charged using the standard charging method at 25 °C, short-circuit the positive and negative terminals of the battery pack’s discharge port with wires (wire resistance 80 ± 20m Ω) for 1 hour. | The battery pack should not leak, ignite, or explode. |
| OverCharge | After charging with the standard charging method at 25 °C, set the constant current source to 1.25 times the nominal voltage and 0.1I (A). | |
| Discharge | Discharge the battery pack to the termination voltage or battery pack protection, and then continue discharging for 5 hours at 0.1I (A). | Visually inspect the appearance and ensure that there is no leakage, smoke, fire, or explosion. |
| Constant Damp Heat Test | After charging using the standard charging method at 25 °C, place it in a constant temperature and humidity chamber at (40 ± 2) °C and relative humidity of 90-95% for 48 hours; After 7 hours of storage, visually inspect. | |
| High and low temperature impact | After charging using the standard charging method at 25 °C, place the battery pack in an environment with a temperature of 75 °C± 2 °C for 6 hours, then move it to an environment with a temperature of -40 °C for 6 hours. The time interval between moving from the highest temperature to the lowest temperature should not exceed 3 minutes. Repeat the above steps, after 10 cycles, remove and let it sit for 24 hours, and visually inspect. |